ASAIO J ; 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38483812

RESUMO

Physical therapy (PT) benefits for critically ill patients are well recognized; however, little data exist on PT in patients receiving temporary mechanical circulatory support. In this single-center retrospective study (February 2017-January 2022), we analyzed 37 patients who received an axillary Impella device (Abiomed, Danvers, MA) and PT to "prehabilitate" them before durable left ventricular assist device (dLVAD) implantation. The Activity Measure for Post-Acute Care (AM-PAC) Basic Mobility tool assessed the functional status at different points during admission. Immediately after Impella placement, the median AM-PAC score was 12.7 (interquartile range [IQR], 9-15), and the scores continued to significantly increase to 18.4 (IQR, 16-23) before dLVAD and up to 20.7 (IQR, 19-24) at discharge, indicating improved independence. No PT-related complications were reported. Thus, we hypothesize that critically ill patients initially deemed equivocal candidates may safely participate in PT while maximizing functional activities before dLVAD placement.

3.
Innovations (Phila) ; 18(5): 489-493, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37710981

RESUMO

The Impella 5.5® (Abiomed, Danvers, MA, USA) is a microaxial flow pump that promotes left ventricular unloading and improves end-organ perfusion before durable left ventricular assist device (LVAD) implantation. Thrombus formation after Impella 5.5 insertion can occur and represents a significant challenge to device explantation. Durable LVAD implantation is typically performed without aortic cross-clamping, so a dislodged thrombus can potentially embolize and lead to catastrophic events. We describe our technique to safely explant an Impella 5.5 in patients who develop a thrombus on the inflow portion of the device before surgical LVAD implantation.

4.
Tex Heart Inst J ; 50(3)2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-37270296

RESUMO

BACKGROUND: This study assessed in-hospital outcomes of patients with chronic systolic, diastolic, or mixed heart failure (HF) undergoing transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR). METHODS: The Nationwide Inpatient Sample database was used to identify patients with aortic stenosis and chronic HF who underwent TAVR or SAVR between 2012 and 2015. Propensity score matching and multivariate logistic regression were used to determine outcome risk. RESULTS: A cohort of 9,879 patients with systolic (27.2%), diastolic (52.2%), and mixed (20.6%) chronic HF were included. No statistically significant differences in hospital mortality were noted. Overall, patients with diastolic HF had the shortest hospital stays and lowest costs. Compared with patients with diastolic HF, the risk of acute myocardial infarction (TAVR odds ratio [OR], 1.95; 95% CI, 1.20-3.19; P = .008; SAVR OR, 1.38; 95% CI, 0.98-1.95; P = .067) and cardiogenic shock (TAVR OR, 2.15; 95% CI, 1.43-3.23; P < .001; SAVR OR, 1.89; 95% CI, 1.42-2.53; P ≤ .001) was higher in patients with systolic HF, whereas the risk of permanent pacemaker implantation (TAVR OR, 0.58; 95% CI, 0.45-0.76; P < .001; SAVR OR, 0.58; 95% CI, 0.40-0.84; P = .004) was lower following aortic valve procedures. In TAVR, the risk of acute deep vein thrombosis and kidney injury was higher, although not statistically significant, in patients with systolic HF than in those with diastolic HF. CONCLUSION: These outcomes suggest that chronic HF types do not incur statistically significant hospital mortality risk in patients undergoing TAVR or SAVR.


Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento , Fatores de Risco , Complicações Pós-Operatórias/epidemiologia , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Doença Crônica , Insuficiência Cardíaca/etiologia , Mortalidade Hospitalar
5.
ASAIO J ; 69(10): e437-e440, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37220217

RESUMO

TandemHeart (Cardiac Assist Inc., Pittsburgh, PA) is a valuable mechanical circulatory support (MCS) device that provides left atrial to femoral artery bypass and directly unloads the left ventricle. The device is inserted under fluoroscopic guidance in the cardiac catheterization laboratory without requiring invasive surgical exposure. However, this device is unique because it directly unloads the oxygenated blood from the left atrium and may be needed for postoperative support in patients undergoing various open cardiac surgeries. In this article, we provide a detailed description of the open surgical insertion of a TandemHeart device.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Coração Auxiliar , Humanos , Ventrículos do Coração/cirurgia , Átrios do Coração
6.
ASAIO J ; 69(7): e354-e359, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-37039827

RESUMO

Frailty and malnutrition in patients with heart failure are barriers to durable left ventricular assist device (D-LVAD) support and heart transplantation. Moreover, cachexia in patients with advanced heart failure carries a high mortality risk. There are no guidelines for these patients other than increased caloric intake and rehabilitation. Patients suffering from cardiac cachexia and heart failure may benefit from temporary, percutaneous assist device support to improve the underlying heart disease and reverse the catabolic state. We retrospectively reviewed patients from January 2017 to January 2022. All patients who received Impella support (5.0 or 5.5, Abiomed) before D-LVAD implantation were screened. Those who met the criteria for cardiac cachexia were included. Patient demographics, nutritional and biochemical markers, and survival data were collected. A total of 14 patients were included. The majority of patients were male (85.7%) with ischemic cardiomyopathy (64.3%). Caloric intake, physical strength, and ambulation improved. Prealbumin levels improved from a median of 13.7-18.0 mg/dl ( p < 0.006) while on Impella 5.0 or 5.5 support. All patients survived to discharge and the 6 month follow-up. In conclusion, use of the Impella device improves cardiogenic shock symptoms and, consequently, may improve cachexia status prior to D-LVAD implantation.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Masculino , Feminino , Estudos Retrospectivos , Caquexia/etiologia , Resultado do Tratamento , Choque Cardiogênico , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/cirurgia
7.
J Heart Lung Transplant ; 42(5): 645-650, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36641296

RESUMO

BACKGROUND: Delayed sternal closure may be required after left ventricular assist device (LVAD) implantation due to coagulopathy or hemodynamic instability. There is conflicting data regarding infection risk. METHODS: We performed a single-center, retrospective analysis of patients who received their first LVAD between May 2012 and January 2021. Patients were divided into delayed sternal closure (DSC) and primary sternal closure (PSC) groups. We used chi-squared or Fisher Exact tests, as appropriate, to compare the incidence of postoperative LVAD-related infections (mediastinal/sternal wound) and LVAD-specific infections (driveline and pump pocket) after definitive chest closure between these two groups. RESULTS: A total of 327 patients met eligibility criteria, including 127 (39%) patients that underwent DSC and 200 (61%) patients that had a PSC. Demographic and clinical characteristics were similar except for an overrepresentation of men (87% vs. 75%, p = .016), Interagency Registry of Mechanically Assisted Circulatory Support class I-II patients (89% vs 66%, p < .001), patients with a previous sternotomy (43% vs 13%, p < .001), and patients with chronic kidney disease (55% vs 43%, p = .030) in the DSC group. The median DSC time was 24 (IQR: 24-48) hours. The incidence of LVAD-related mediastinal/sternal wound infection was similar between the DSC and PSC groups (4.7% vs 3.0%, p = .419). There was no difference between DSC and PSC groups in the incidence of driveline infection (6.3% vs 9%, p = .411) and pump pocket infection (1.6% vs 1.5%, p =.901), respectively. CONCLUSIONS: DSC does not seem to increase the incidence of LVAD-related or LVAD-specific infection rates in heart failure patients undergoing device implantation surgery.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Masculino , Humanos , Estudos Retrospectivos , Coração Auxiliar/efeitos adversos , Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/epidemiologia , Esternotomia/efeitos adversos , Complicações Pós-Operatórias , Resultado do Tratamento
8.
Perfusion ; 38(6): 1196-1202, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-35766358

RESUMO

INTRODUCTION: Advanced age is a known risk factor for poor outcomes after veno-arterial extracorporeal membrane oxygenation (V-A ECMO) for cardiac support. The use of ECMO support in patients over the age of 80 is controversial, and sometimes its use is contraindicated. We aimed to assess the use of ECMO in octogenarian patients to determine survival and complication rates. METHODS: A single-center, retrospective analysis was completed at a large, urban academic medical center. Patients requiring V-A ECMO support between December of 2012 and November of 2019 were included as long as the patient was at least 80 years of age at the time of cannulation. Post cardiotomy shock patients were excluded. RESULTS: A total of 46 patients met eligibility criteria; all received V-A ECMO support. Overall, the majority of patients (71.7%; 33/46) survived to decannulation, and 43.5% (20/46) survived to discharge. Patients who were previously rescued from percutaneous interventions tend to have a better survival than other patients (p = .06). The most common complications were renal and hemorrhagic. CONCLUSIONS: We demonstrated that advanced age alone should not disqualify patients from cannulating and supporting with V-A ECMO.


Assuntos
Oxigenação por Membrana Extracorpórea , Idoso de 80 Anos ou mais , Humanos , Oxigenação por Membrana Extracorpórea/efeitos adversos , Estudos Retrospectivos , Octogenários , Fatores de Risco , Alta do Paciente
9.
Tex Heart Inst J ; 49(6)2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-36450144

RESUMO

Minimally invasive aortic valve replacement through a right thoracotomy is frequently performed in patients with aortic valve disease. The Cor-Knot Device (LSI Solutions) is an automated fastener that secures valve sutures. This case report is for a patient who developed postcardiotomy shock during a minimally invasive aortic valve surgery. The patient was found to have an aortic root dissection involving 90% of the aortic root circumference, including bilateral coronary ostia. The autopsy revealed that the aortic damage could be explained by a direct aortic intimal tear from the distal tip of the device shaft. The device was most likely not in perfect apposition to the sewing ring because of the restricted angle and space between the ribs.


Assuntos
Dissecção Aórtica , Humanos , Dissecção Aórtica/diagnóstico , Dissecção Aórtica/etiologia , Dissecção Aórtica/cirurgia , Aorta , Coração , Toracotomia , Suturas
10.
Innovations (Phila) ; 17(5): 377-381, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36189791

RESUMO

Acute decompensated refractory cardiogenic shock is an emergency in which the prompt instauration of mechanical circulatory support improves outcomes. The typical, initial approach for device delivery is via femoral vessels due to easy access and safety. If longer support is needed, the femoral access will severely impair the patient's mobility and can also limit the amount of support given as the new-generation devices are too large for direct arterial insertion. Upper-body arterial conduits (UBACs) are used for the delivery of larger, percutaneous ventricular assist devices (pVADs). The Impella 5.5 (Abiomed, Danvers, MA, USA) is a pVAD that can be deployed through a UBAC by either axillary/subclavian access or a transaortic approach. The latter approach is typically used in cases of postcardiotomy shock, in which the ascending aorta is already exposed through a full sternotomy. However, in some cases, the axillary artery is not suitable due to size (<6 mm in diameter), and a smaller pVAD is delivered into the heart. To avoid providing suboptimal support, we present an alternative, minimally invasive approach in which the larger device is delivered through the ascending aorta. This article summarizes the details of this approach through a mini upper partial sternotomy and reviews the relevant technical considerations.


Assuntos
Artéria Axilar , Coração Auxiliar , Humanos , Artéria Axilar/cirurgia , Esternotomia , Choque Cardiogênico/cirurgia , Resultado do Tratamento
11.
Ann Cardiothorac Surg ; 11(3): 304-309, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35733711

RESUMO

The outcomes of patients with acute myocardial infarctions (AMI) have significantly improved with advances in early reperfusion strategies; however, patients with massive infarcts or those who do not receive timely revascularization may develop mechanical complications of AMI. The most common mechanical complications are ventricular septal rupture (VSR), acute mitral regurgitation (MR) due to papillary muscle rupture, and free-wall rupture. Each complication is associated with a high risk of morbidity and mortality, and requires a multidisciplinary approach for prompt diagnosis and hemodynamic stabilization. Surgery is the mainstay of therapy but is associated with poor outcomes if performed too early during the treatment course for VSR or if performed too late with MR and free wall rupture. Optimal timing for surgery in combination with temporary circulatory support may be a feasible strategy for better results.

13.
Perfusion ; 37(5): 477-483, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-33926332

RESUMO

BACKGROUND: Respiratory failure (RF) is a common cause of death and morbid complication in trauma patients. Extracorporeal membrane oxygenation (ECMO) is increasingly used in adults with RF refractory to invasive mechanical ventilation. However, use of ECMO remains limited for this patient population as they often have contraindications for anticoagulation. STUDY DESIGN: Medical records were retroactively searched for all adult patients who were admitted to the trauma service and received veno-venous ECMO (VV ECMO) support between June 2015 and August 2018. Survival to discharge and ECMO-related complications were collected and analyzed. RESULTS: Fifteen patients from a large Level I trauma center met the criteria. The median PaO2/FiO2 ratio was 53.0 (IQR, 27.0-76.0), median injury severity score was 34.0 (IQR, 27.0-43.0), and the median duration of ECMO support was 11 days (IQR, 7.5-20.0). For this cohort, the survival-to-discharge rate was 87% (13/15). The incidence of neurologic complications was 13%, and deep vein thrombosis was reported in two cases (13%). CONCLUSIONS: Survival rates of trauma patients in this study are equivalent to, or may exceed, those of non-trauma patients who receive ECMO support for other types of RF. With the employment of a multidisciplinary team assessment and proper patient selection, early cannulation, traumatic RF may be safely supported with VV ECMO in experienced centers.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Respiratória , Adulto , Oxigenação por Membrana Extracorpórea/efeitos adversos , Humanos , Alta do Paciente , Respiração Artificial , Insuficiência Respiratória/etiologia , Insuficiência Respiratória/terapia , Estudos Retrospectivos , Resultado do Tratamento
14.
A A Pract ; 15(11): e01545, 2021 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-34752439

RESUMO

The increasing coincidence of obesity with heart failure may preclude eligibility for orthotopic heart transplantation, requiring continuous-flow left ventricular assist devices (LVADs) as destination therapy. This report describes intraoperative considerations for patients who underwent LVAD implantation with concurrent laparoscopic sleeve gastrectomy (LSG) to promote weight loss. In particular, right ventricular dysfunction associated with acute left ventricular unloading may be compounded by pneumoperitoneum for LSG due to the difficulty in ventilating patients with obesity, hypercarbia-mediated increase in pulmonary vascular resistance, and variable cardiac loading conditions. We identify specific anesthetic challenges and discuss methods of monitoring and management.


Assuntos
Coração Auxiliar , Laparoscopia , Obesidade Mórbida , Gastrectomia , Humanos , Obesidade Mórbida/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
15.
Interact Cardiovasc Thorac Surg ; 33(1): 136-138, 2021 06 28.
Artigo em Inglês | MEDLINE | ID: mdl-34118156

RESUMO

We present the case of a 47-year-old male patient with a history of symptomatic paroxysmal atrial fibrillation who failed guideline-directed medical treatment and cardioversion. Electrical mapping was attempted and complicated with catheter entrapping in the mitral valve (MV) apparatus, and multiple attempts for retrieval were unsuccessful and caused severe valvular dysfunction. Emergent valve replacement was required secondary to the extensive disruption of the valvular apparatus and posterior annulus. Mapping catheter entrapment in the valvular apparatus is an uncommon complication, but when it occurs, there is a high risk of injury to the MV apparatus during retrieval. To avoid extensive MV damage, operators should use minimal force during standard manoeuvres to extract the catheter. If gentle retrieval manoeuvres fail, surgical exploration and open retrieval may prevent MV damage. Early surgical consultation and exploration could result in open catheter retrieval or MV repair versus MV replacement.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Insuficiência da Valva Mitral , Fibrilação Atrial/cirurgia , Fibrilação Atrial/terapia , Cateteres , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
16.
Tex Heart Inst J ; 48(1)2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-33946106

RESUMO

Continuous-flow left ventricular assist device implantation is the typical treatment for end-stage heart failure. Improvements in device engineering and technology, surgical experience and technique, and perioperative management have advanced the field, and short-term results approach those of heart transplantation. Further improvements may be achieved by minimizing adverse physiologic effects associated with cardiopulmonary bypass. Therefore, we have developed an off-pump implantation approach for continuous-flow left ventricular assist devices. We detail our surgical technique for off-pump implantation of the HeartWare device.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Insuficiência Cardíaca/cirurgia , Coração Auxiliar , Implantação de Prótese/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
17.
ESC Heart Fail ; 8(2): 1615-1619, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33491335

RESUMO

Patients who suffer morbid obesity and heart failure (HF) present unique challenges. Two cases are described where concomitant use of laparoscopic sleeve gastrectomy (LSG) and left ventricular assist device (LVAD) placement enabled myocardial recovery and weight loss resulting in explantation. A 29-year-old male patient with a body mass index (BMI) of 59 kg/m2 and severe HF with a left ventricular ejection fraction (LVEF) of 20-25% underwent concomitant LSG and LVAD placement. Sixteen months after surgery, his BMI was reduced to 34 kg/m2 and his LVEF improved to 50-55%. A second 41-year-old male patient with a BMI of 44.8 kg/m2 with severe HF underwent the same procedures. Twenty-four months later, his BMI was 31.1 kg/m2 and his LVEF was 50-55%. In both cases, the LVAD was successfully explanted and patients remain asymptomatic. HF teams should consult and collaborate with bariatric experts to determine if LSG may improve the outcomes of their HF patients.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Adulto , Gastrectomia , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/cirurgia , Humanos , Masculino , Estudos Retrospectivos , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
18.
ASAIO J ; 67(6): e107-e109, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-33112528

RESUMO

Left ventricular assist devices (LVADs) implanted into patients with heart failure sometimes develop insufficient forward flow due to malfunction of the outflow graft. One increasingly seen source of outflow graft malfunction is the development of external compression of the outflow graft (ECOG) due to the accumulation of material between the flexible outflow graft and the relatively rigid overlying Gore-Tex tubular graft. When there is segmental ECOG, a percutaneous approach with outflow graft stent placement is the treatment of choice. However, we have encountered cases with diffuse ECOG for which surgery appeared to be a superior choice. We, therefore, developed a minimally invasive surgical approach in which a mini-thoracotomy, rather than redo-sternotomy, is combined with unroofing of the Gore-Tex graft and subsequent evacuation of the organized hematoma. We describe this technique in two patients with diffuse ECOG in whom we found the method to be simple, relatively rapid, and very effective.


Assuntos
Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Politetrafluoretileno
19.
Perfusion ; 36(4): 358-364, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33233987

RESUMO

The Coronavirus Disease 2019 (COVID-19) pandemic has required rapid and effective protocol adjustments at every level of healthcare. The use of extracorporeal membrane oxygenation (ECMO) is pivotal to COVID-19 treatment in cases of refractory hypoxemic hypercapnic respiratory failure. As such, our large, metropolitan air ambulance system in conjunction with our experts in advanced cardiopulmonary therapies modified protocols to assist peripheral hospitals in evaluation, cannulation and initiation of ECMO for rescue and air transportation of patients with COVID-19 to our quaternary center. The detailed protocol is described alongside initial data of its use. To date, 14 patients have been placed on ECMO support at an outside facility and successfully transported via helicopter to our hub hospital using this protocol.


Assuntos
Resgate Aéreo , COVID-19/terapia , Oxigenação por Membrana Extracorpórea , Transporte de Pacientes , Adulto , Cuidados Críticos/métodos , Oxigenação por Membrana Extracorpórea/métodos , Feminino , Humanos , Unidades de Terapia Intensiva , Masculino , Estudos Retrospectivos , SARS-CoV-2/isolamento & purificação , Transporte de Pacientes/métodos
20.
A A Pract ; 14(14): e01355, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33278087

RESUMO

Symptomatic carotid artery disease stenosis warrants open surgical carotid endarterectomy (CEA). However, patients with continuous-flow left ventricular assist devices (CF-LVADs) present unique challenges when vasopressors and volume are used to maintain cerebral perfusion pressure after carotid cross-clamping. This report describes patients with CF-LVADs who underwent CEA. We identify how preload, contractility, afterload, pump speed, mean arterial pressure, and anticoagulation should be addressed to maintain CF-LVAD outflow and cerebral perfusion during the procedure. Anesthesiologists can combine an understanding of continuous-flow physiology with invasive monitors to optimize cardiac output and cerebral blood flow during CEA procedures.


Assuntos
Estenose das Carótidas , Endarterectomia das Carótidas , Coração Auxiliar , Estenose das Carótidas/cirurgia , Circulação Cerebrovascular , Humanos , Vasoconstritores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...